Starting Force Test

Starting Force Test
Starting Force Test
Send Inquiry
Product Code : 37
Product Description

For Starting Force Test, we have installed a fully assembled centralizer which is easily  installed over four equally space hinges. Our test assembly is held within 5 degrees of the vertical. Along with the centralizer resting on the edge of the outer pipe B, load is applied on the inner pipe to pull the centralizer into a outer piper B. Starting force equals the maximum force required to start centralizer inside pipe B. The starting force should be less than the weight of 40ft.(12.2 mtrs) of medium weight casing.

Technical Specifications

Casing size in inches

Starting Force (max)

Resorting Force (min)

4 1/2

464

464

5

520

520

5 1/2

620

620

6 5/8

960

960

7

1040

1040

7 5/8

1056

1056

8 5/8

1440

1440

9 5/8

1600

1600

10 3/4

2040

1020

11 3/4

2160

1080

13 3/8

2440

1200

16

2600

1300

18 5/8

3500

1750

20

3760

1880